500 KVA Greaves Genius Generator Set
500 KVA Greaves Genius Generator Set Specification
- Standard
- ISO 9001, CPCB II Compliant
- Poles Number
- 4
- Insulation
- Class H
- Dimension (L*W*H)
- 4800 x 1700 x 2500 mm
- Fuel Consumption
- Approx. 98 Ltr/hr at 100% load
- Fuel Tank Capacity
- 800 Litres
- Pressure
- 17.5:1 Compression Ratio
- Engine Type
- 4 Stroke, Turbocharged, Aftercooled Diesel Engine
- Alternator
- Brushless, Stamford Type
- Bore *Stroke
- 138 mm x 165 mm
- Engine Model
- Greaves 16L 13.5 TD
- Protection Class
- IP23
- Product Type
- Greaves Genius Generator Set
- Output Type
- AC Three Phase
- Rated Power
- 500 KVA
- Rated Voltage
- 415 V
- Starting Type
- Auto/Manual
- Rated Frequency
- 50 Hz
- Power Range
- 500 KVA
- Color
- White & Blue
- Cooling System
- Water Cooled
- Noise Level
- 75 dB(A) at 1 m
- Phase
- Three Phase
- Speed
- 1500 RPM
- Weight
- 6000 kg (approx)
- Emission Compliance
- CPCB II Norms
- Battery Voltage
- 2 x 12V, 180AH
- Altitude Capability
- Up to 1000 m above sea level
- Lubricating Oil Capacity
- 37 Litres
- Relative Humidity
- Up to 90% (Non-condensing)
- Controller Type
- Microprocessor-based Automatic Mains Failure (AMF) Panel
- Starting System
- Heavy Duty Electric Starter Motor
- Voltage Regulation
- +/- 1%
- Genset Enclosure
- Soundproof, Weatherproof Canopy
- Engine Aspiration
- Turbocharged and Aftercooled
- Exhaust Temperature
- 500 °C (Approx)
About 500 KVA Greaves Genius Generator Set
Being a client-oriented company in this sector, we are deeply involved in proposing the best-in-quality 500 KVA Greaves Used Generator Set. Suitable for hospitals, manufacturing industry, companies, apartments, guest houses, and so on, it is perfectly optimized by our expert professionals using top-grade spare parts & components to guarantee its outstanding performance, fuel efficiency, and longer service life. Comes in varied sizes and models, our 500 KVA Greaves Used Generator Set is easy to install, low maintenance, durable and cost-effective.
Advanced Control and Reliability
Equipped with a microprocessor-based AMF panel, the generator automatically detects mains failure and switches to backup power, minimizing downtime. The robust electric starter motor ensures reliable engine starts while advanced voltage regulation (+/-1%) enhances power quality for sensitive equipment.
Durable Build and Compliance
The enclosure is both soundproof and weatherproof, reducing noise to just 75 dB(A) and ensuring durability in outdoor settings. The generator complies with CPCB II and ISO 9001 standards for safety and environmental protection, making it a conscientious choice for varied Indian climates and regulations.
Operational Efficiency
Optimized for demanding environments, the unit features turbocharged and aftercooled aspiration, a 37-liter lubricating oil capacity, and water cooling for sustained performance. Handling up to 90% relative humidity and altitudes of 1000 meters, it remains dependable in challenging operational contexts.
FAQ's of 500 KVA Greaves Genius Generator Set:
Q: How does the microprocessor-based AMF panel enhance generator operation?
A: The Automatic Mains Failure (AMF) panel uses a microprocessor to detect utility outages and automatically starts the generator, ensuring uninterrupted power supply. It also manages safe changeover back to mains once restored, which reduces manual intervention and improves reliability.Q: What are the key benefits of the Greaves Genius 500 KVA Generator's soundproof enclosure?
A: The soundproof, weatherproof enclosure significantly lowers noise emission to 75 dB(A) at 1 meter, safeguarding workplace comfort and meeting regulatory standards. It also protects the genset from environmental factors, enhancing durability and service life.Q: Where can this generator set be utilized effectively in India?
A: It is ideal for industrial plants, commercial complexes, hospitals, data centers, and manufacturing units across India, given its CPCB II compliance, robust build, and ability to handle high humidity and moderate altitudes.Q: When should routine maintenance be performed on the generator?
A: Routine maintenance should be scheduled as recommended by the manufacturer-typically every 250 hours or quarterly. Key tasks include lubricating oil checks, filter replacements, and inspection of electrical and cooling systems to ensure continuous, efficient operation.Q: What process is followed during automatic starting and stopping of the genset?
A: On detecting a mains power failure, the AMF panel automatically starts the generator using the heavy-duty electric starter motor. Once the utility power resumes, the panel safely switches back to mains supply and shuts down the generator, all without manual intervention.Q: How is voltage regulated and why is it important for equipment safety?
A: The generator's voltage regulation of +/-1% is managed by an automatic voltage regulator. This consistent output protects sensitive machinery and electronic devices from fluctuations, ensuring their operational safety and longevity.Q: What are the usage advantages of water cooling and turbocharged, aftercooled engine design?
A: Water cooling maintains optimal engine temperatures under heavy loads, while turbocharging and aftercooling improve combustion efficiency and power output. Together, they enable the generator to run efficiently for extended periods, even under high-demand conditions.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Generator Set Category
1010KVA Onwards Greaves Genius Generator Set
Power Range : 1010KVA Onwards
Product Type : Generator Set
Color : White
Rated Power : 1010 KVA
Phase : Three Phase
Output Type : AC
100 KVA Greaves Genius Generator Set
Power Range : 100 KVA
Product Type : Diesel Generator
Color : White
Rated Power : 100 KVA
Phase : Three Phase
Output Type : AC Output
82.5 KVA Greaves Genius Generator Set
Power Range : 82.5 KVA
Product Type : Generator Set
Color : White
Rated Power : 82.5 KVA
Phase : Not Visible, Other
Output Type : Not Visible
500 KVA Greaves Genius DG Set
Power Range : 500 KVA
Product Type : DG Set
Color : White
Rated Power : 500 KVA
Phase : 3 Phase, Other
Output Type : Placeholder value
![]() |
IMPERIAL GENERATORS & ELECTRICALS